logo

SANIpore® DS|HT

High-Temperature Resistant Sterilizing Grade Filter

SANIpore® DS|HT filters are bacterial retention cartridge filters and are the first choice in the high-temperature industry because they can be used for high-temperature liquids up to 203℉.

Considering the reduced replacement cost for our customers, SANIpore® DS|HT filters have a long service life because it consist of two layers of polyethersulfone (PES)membrane for filtration, which retains a large number of bacteria and other particles in the pre-filter.

The SANIpore® DS|HT provides various configurations including cartridges and capsule filters.  Bioburden prefilter pore sizes range from 0.10 to 1.2 µm. Final filter pore sizes range from 0.03 to 0.65 µm.

SANIpore® DS|HT

Features and Quality

  • Double-layer membrane structure provides excellent relibility and safety
  • First choice in the high temperature industry
  • Asymmetric pre-filter layer for longer service life and more economical costs
  • Large effective filtration area
  • Can be steam sterilized up to 50 sterilization cycles
  • Complies with Food Contact Regulations: FDA 21CFR177-182 and 1935/2004 EC
Features and Quality

Construction of Materials

Filter Membrane Double-Layer PES Membrane
Media Support Polypropylene
End Caps Polypropylene
Inner Core Polypropylene
Outer Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton(or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Maximum Operating Parameters

CARTRIDGES
Operating Temperature (water) 203 °F at 30 psid (95 °C at 2.07 bard)
Forward Differential Pressure 80 psid at 68 °F (5.52 bard at 20 °C)
Reverse Differential Pressure 50 psid at 68 °F (3.45 bard at 20 °C)
Recommended Changeout Pressure 35 psid (2.41 bard)
O-rings Buna, Viton (or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Cartridge Integrity Test Specifications

Pore size Minimum Bubble point
0.1um 32PSI/2.2barg (IPA)
0.2um 55.1PSI/3.8barg(water)
0.45um 39.2/2.7barg(water)

Integrity Testing

PORE SIZE DIFFUSION TEST PRESSURE
µm PSIG BARG
0.03 60 4.13
0.10 48 3.30
0.22 35 2.41
0.45 20 1.37
0.65 15 1.03

Sanitization/Sterilization

Filtered Hot Water 90 °C (194 °F), 30 minutes, multiple cycles, max 3 psid forward flow
Inline Steam 275 °F (135 °C), 30 min, 25+ cycles
Autoclave 250 °F (121 °C), 30 min, 25+ cycles
0.45um 39.2/2.7barg(water)

 

*Cartridge Filters – For all elevated temperature procedures above, a stainless-steel support ring is required.

618 51 1010 30 01 S A P
Filter Type
618=SANIpore® DS|HT
Filter Configuration
51=Cartridge
Pore Size
1010=0.1um
2020=0.22um
4545=0.45um
Filter Size
30=5″
31=10″
33=20″
34=30″
35=40″
Connector
01=222Fin
02=222Flat
03=226Fin
04=226Flat
05=DOE
O-Ring
S=Silicone
E=EPDM
V=Viton
Sterilization
A=Autoclave
P=Pharmaceutical
grade

Features and Quality

Features and Quality
  • Double-layer membrane structure provides excellent relibility and safety
  • First choice in the high temperature industry
  • Asymmetric pre-filter layer for longer service life and more economical costs
  • Large effective filtration area
  • Can be steam sterilized up to 50 sterilization cycles
  • Complies with Food Contact Regulations: FDA 21CFR177-182 and 1935/2004 EC

Specification and Data

Construction of Materials

Filter Membrane Double-Layer PES Membrane
Media Support Polypropylene
End Caps Polypropylene
Inner Core Polypropylene
Outer Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton(or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Maximum Operating Parameters

CARTRIDGES
Operating Temperature (water) 203 °F at 30 psid (95 °C at 2.07 bard)
Forward Differential Pressure 80 psid at 68 °F (5.52 bard at 20 °C)
Reverse Differential Pressure 50 psid at 68 °F (3.45 bard at 20 °C)
Recommended Changeout Pressure 35 psid (2.41 bard)
O-rings Buna, Viton (or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Cartridge Integrity Test Specifications

Pore size Minimum Bubble point
0.1um 32PSI/2.2barg (IPA)
0.2um 55.1PSI/3.8barg(water)
0.45um 39.2/2.7barg(water)

Integrity Testing

PORE SIZE DIFFUSION TEST PRESSURE
µm PSIG BARG
0.03 60 4.13
0.10 48 3.30
0.22 35 2.41
0.45 20 1.37
0.65 15 1.03

Sanitization/Sterilization

Filtered Hot Water 90 °C (194 °F), 30 minutes, multiple cycles, max 3 psid forward flow
Inline Steam 275 °F (135 °C), 30 min, 25+ cycles
Autoclave 250 °F (121 °C), 30 min, 25+ cycles
0.45um 39.2/2.7barg(water)

 

*Cartridge Filters – For all elevated temperature procedures above, a stainless-steel support ring is required.

Ordering Information

618 51 1010 30 01 S A P
Filter Type
618=SANIpore® DS|HT
Filter Configuration
51=Cartridge
Pore Size
1010=0.1um
2020=0.22um
4545=0.45um
Filter Size
30=5″
31=10″
33=20″
34=30″
35=40″
Connector
01=222Fin
02=222Flat
03=226Fin
04=226Flat
05=DOE
O-Ring
S=Silicone
E=EPDM
V=Viton
Sterilization
A=Autoclave
P=Pharmaceutical
grade

Common questions about Sanitek

Common Questions about SanitekWhat is the asymmetric PES?

The size of the apertures changes along the membrane’s thickness, with the greatest openings appearing on one side and the smallest openings on the other. Each side of the membrane appears slightly different when viewed with reflected light at low incidence angles. In comparison to the side with the smallest pores, the side with the greatest pores will appear more matte or dull (which will appear shinier).

The majority of people can quickly distinguish the sides if they have some experience. Without effecting retention, the membranes can be utilized with either surface pointed upstream. However, pointing the bright side upstream enables more accurate examinations of the retained particles while orienting the dull side upstream boosts overall throughput.

Common Questions about SanitekHow do you assure the quality of your products?

At Sanitek, we pay attention to the details of every link and strictly adhere to ISO 9001:2008 and ISO 13485:2005 standards to ensure the quality of our products.

In the raw material procurement phase, we work with reliable suppliers to ensure that the quality of raw materials meets our standard requirements.

In the production process, we strictly control the quality of each link to ensure that the manufacturing process of the product is stable and reliable. At the factory inspection stage of the final product, we carry out a comprehensive quality check to ensure that the product meets the customer’s requirements and specifications.

Common Questions about SanitekWhat support can I expect from Sanitek in case of issues?

In case of any issues, Sanitek will respond promptly to assist you in analyzing the problem and finding out the cause. We retain the raw material of all shipments, which is essential for identifying if the issue originates from the membrane. While incidents are extremely rare, if the problem is confirmed to be from the membrane, we will take corrective action, including prioritized full replacement of the affected lot.

Need Help?

You can find the right application or product using our Tool, or through our Chat Bot.

Let's help you find the right filter for
your critical filtration.

Talk to us

error: Content is protected !!