SANIpore® UNY filters are designed for ultrafine particle removal in ultrapure water, chemicals, solvents, and other aqueous solutions. For customers who have this need, the SANIpore® UNY filter is a good choice. In terms of manufacturing, we have adopted a nylon6,6 media with good characteristics.

With pore sizes ranging from 0.10 to 0.65 µm, these filters are versatile and can be used across various applications. Whether in laboratory-scale or full production, the use of identical materials guarantees consistent and reliable filtration results.

SANIpore® UNY

Features and Quality

  • Rigorously 100% Integrity Tested
  • Compliant with FDA Food Contact Regulations
  • Utilizes Thermal Bonding
  • Non-Fiber Releasing
Features and Quality

Construction of Materials

Filter Membrane Nylon6,6 Membrane
Media Support Polypropylene
End Caps Polypropylene
Inner Core Polypropylene
Outer Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton (or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Maximum Operating Parameters

Differential Pressure ●Forward 50 psid (3.4 bard)at 20 C(68 °F)

●Reverse 40 psid (2.7 bard) at 20 C(68 °F)

Operating Temperature 82 C(180 °F) at 10 psid(0.69 barg) in water
Recommended Changeout Pressure 35psid(2 .4barg)

Filtration Area (Nominal)

CAPSULES CARTRIDGES AND CAPSULES ARTRIDGES
Length 2” 5” 10” 20” 30” 40”
5.08cm 12.7cm 25.4cm 50.8cm 76.2cm 101.6cm
Area 1.2 ft2 3.3 ft2 7.0 ft2 14.0 ft2 21.0 ft 28.0 ft2
0.11m2 0.30m2 0.65m2 1.30m2 1.95m2 2.60m2

Water Flow Characteristic

Water Flow Characteristic-UNY

613 51 0010 30 01 S A P
Filter Type
613=SANIpore® UNY
Filter Configuration
51=Cartridge
Pore Size
0010=0.1um
0020=0.22um
0045=0.45um
0065=0.65m
Filter Size
30=5″
31=10″
33=20″
34=30″
35=40″
Connector
01=222Fin
02=222Flat
03=226Fin
04=226Flat
05=DOE
O-Ring
S=Silicone
E=EPDM
V=Viton
Sterilization
A=Autoclave
P=Pharmaceutical
grade

Notice: Due to filter has variety in design, please contact with BROTHER sales for more information

Features and Quality

Features and Quality
  • Rigorously 100% Integrity Tested
  • Compliant with FDA Food Contact Regulations
  • Utilizes Thermal Bonding
  • Non-Fiber Releasing

Specification and Data

Construction of Materials

Filter Membrane Nylon6,6 Membrane
Media Support Polypropylene
End Caps Polypropylene
Inner Core Polypropylene
Outer Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton (or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Maximum Operating Parameters

Differential Pressure ●Forward 50 psid (3.4 bard)at 20 C(68 °F)

●Reverse 40 psid (2.7 bard) at 20 C(68 °F)

Operating Temperature 82 C(180 °F) at 10 psid(0.69 barg) in water
Recommended Changeout Pressure 35psid(2 .4barg)

Filtration Area (Nominal)

CAPSULES CARTRIDGES AND CAPSULES ARTRIDGES
Length 2” 5” 10” 20” 30” 40”
5.08cm 12.7cm 25.4cm 50.8cm 76.2cm 101.6cm
Area 1.2 ft2 3.3 ft2 7.0 ft2 14.0 ft2 21.0 ft 28.0 ft2
0.11m2 0.30m2 0.65m2 1.30m2 1.95m2 2.60m2

Water Flow Characteristic

Water Flow Characteristic-UNY

Ordering Information

613 51 0010 30 01 S A P
Filter Type
613=SANIpore® UNY
Filter Configuration
51=Cartridge
Pore Size
0010=0.1um
0020=0.22um
0045=0.45um
0065=0.65m
Filter Size
30=5″
31=10″
33=20″
34=30″
35=40″
Connector
01=222Fin
02=222Flat
03=226Fin
04=226Flat
05=DOE
O-Ring
S=Silicone
E=EPDM
V=Viton
Sterilization
A=Autoclave
P=Pharmaceutical
grade

Notice: Due to filter has variety in design, please contact with BROTHER sales for more information

Common questions about Sanitek

Common Questions about SanitekHow do you assure the quality of your products?

At Sanitek, we pay attention to the details of every link and strictly adhere to ISO 9001:2008 and ISO 13485:2005 standards to ensure the quality of our products.

In the raw material procurement phase, we work with reliable suppliers to ensure that the quality of raw materials meets our standard requirements.

In the production process, we strictly control the quality of each link to ensure that the manufacturing process of the product is stable and reliable. At the factory inspection stage of the final product, we carry out a comprehensive quality check to ensure that the product meets the customer’s requirements and specifications.

Common Questions about SanitekHow should I order? Who should I contact and how long does it take for material to arrive?

Contact us directly for full details or email us at sales@sanitekfilter.com. And we will get back to you as soon as possible.

Regarding the arrival time of materials, the specific delivery time may vary depending on the product inventory and shipping distance, please inquire about the specific delivery time when contacting the sales team. We will do our best to ensure that you receive the required materials in a timely manner.

Common Questions about SanitekCan cartridge filters be used for sterile gas applications?

Yes, cartridge filters have a highly effective microbial retention capacity to effectively remove microbial contaminants from the air, ensuring a sterile environment. In addition, Sanitek PTFE cartridge filters have good chemical and can be used under a variety of harsh process conditions. Therefore, for applications requiring sterile gases, Sanitek PTFE cartridge filters are a reliable choice.

Need Help?

You can find the right application or product using our Tool, or through our Chat Bot.

Let's help you find the right filter for
your critical filtration.

Talk to us

error: Content is protected !!
Open chat
Scan the code
Hello
Can we help you?