logo

SANIpure® PP3

Particle & Bioburden Reduction Filter Cartridges

The SANIpure® PP3 cartridge filters feature pleated Polypropylene Depth Media, tailored for prefiltering critical process liquids, including water, chemicals, and solvents in pharmaceutical industries.

With a 99.9% efficiency rating at the specified pore size, these filters ensure reliable and efficient filtration performance. Therefore SANIpure® PP3 is the ideal choice for particle retention and protection of downstream equipment for all product contact applications.

SANIpure® PP3

Features and Quality

  • Wide chemical compatiblity
  • High dirt hold capacity
  • High retention
  • Thermal bonding
  • Non-fiber releasing
Features and Quality

Construction of Materials

Filter Membrane Borosilicate Microfiber
Media Support Polypropylene
End Caps Polypropylene
Inner Core Polypropylene
Outer Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton(or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Maximum Operating Parameters

Differential Pressure ●Forward 50 psid (3.4 bard)at 20 C(68 °F)

●Reverse 40 psid (2.7 bard) at 20 C(68 °F)

Operating Temperature 82 C(180 °F) at 10 psid(0.69 barg) in water
Recommended Changeout Pressure 35psid(2 .4barg)

Filtration Area (Nominal)

CAPSULES CARTRIDGES AND CAPSULES ARTRIDGES
Length 2” 5” 10” 20” 30” 40”
5.08cm 12.7cm 25.4cm 50.8cm 76.2cm 101.6cm
Area 1.0 ft2 3.0 ft2 6.24 ft2 12.48ft2 18.72 ft2 24.96 ft2
0.58m2 1.16m2 1.74m2 2.32m2

Water Flow Characteristic

Water Flow Characteristic-PP3

603 51 0045 30 01 S A P
Filter Type
602=SANIpure® PP3
Fliter Configuration
51=Cartridge
Pore Size
0045=0.45um
0065=0.65um
0100=1.0um
0300=3.0um
0500=5.0um
1000=10um
2000=20um
Filter Size
30=5″
31=10″
33=20″
34=30″
35=40″
Connector
01=222Fin
02=222Flat
03=226Fin
04=226Flat
05=DOE
O-Ring
S=Silicone
E=EPDM
V=Viton
Sterilization
A=Autoclave
P=Pharmaceutical
grade

Notice: Due to filter has variety in design, please contact with BROTHER sales for more information

Features and Quality

Features and Quality
  • Wide chemical compatiblity
  • High dirt hold capacity
  • High retention
  • Thermal bonding
  • Non-fiber releasing

Specification and Data

Construction of Materials

Filter Membrane Borosilicate Microfiber
Media Support Polypropylene
End Caps Polypropylene
Inner Core Polypropylene
Outer Cage Polypropylene
Sealing Method Thermal Bonding
O-rings Buna, Viton(or FKM), EP, Silicone, Encapsulated   Silicone, Encapsulated Viton (or FKM)

Maximum Operating Parameters

Differential Pressure ●Forward 50 psid (3.4 bard)at 20 C(68 °F)

●Reverse 40 psid (2.7 bard) at 20 C(68 °F)

Operating Temperature 82 C(180 °F) at 10 psid(0.69 barg) in water
Recommended Changeout Pressure 35psid(2 .4barg)

Filtration Area (Nominal)

CAPSULES CARTRIDGES AND CAPSULES ARTRIDGES
Length 2” 5” 10” 20” 30” 40”
5.08cm 12.7cm 25.4cm 50.8cm 76.2cm 101.6cm
Area 1.0 ft2 3.0 ft2 6.24 ft2 12.48ft2 18.72 ft2 24.96 ft2
0.58m2 1.16m2 1.74m2 2.32m2

Water Flow Characteristic

Water Flow Characteristic-PP3

Ordering Information

603 51 0045 30 01 S A P
Filter Type
602=SANIpure® PP3
Fliter Configuration
51=Cartridge
Pore Size
0045=0.45um
0065=0.65um
0100=1.0um
0300=3.0um
0500=5.0um
1000=10um
2000=20um
Filter Size
30=5″
31=10″
33=20″
34=30″
35=40″
Connector
01=222Fin
02=222Flat
03=226Fin
04=226Flat
05=DOE
O-Ring
S=Silicone
E=EPDM
V=Viton
Sterilization
A=Autoclave
P=Pharmaceutical
grade

Notice: Due to filter has variety in design, please contact with BROTHER sales for more information

Common questions about Sanitek

Common Questions about SanitekHow do you assure the quality of your products?

At Sanitek, we pay attention to the details of every link and strictly adhere to ISO 9001:2008 and ISO 13485:2005 standards to ensure the quality of our products.

In the raw material procurement phase, we work with reliable suppliers to ensure that the quality of raw materials meets our standard requirements.

In the production process, we strictly control the quality of each link to ensure that the manufacturing process of the product is stable and reliable. At the factory inspection stage of the final product, we carry out a comprehensive quality check to ensure that the product meets the customer’s requirements and specifications.

Common Questions about SanitekHow should I order? Who should I contact and how long does it take for material to arrive?

Contact us directly for full details or email us at sales@sanitekfilter.com. And we will get back to you as soon as possible.

Regarding the arrival time of materials, the specific delivery time may vary depending on the product inventory and shipping distance, please inquire about the specific delivery time when contacting the sales team. We will do our best to ensure that you receive the required materials in a timely manner.

Common Questions about SanitekCan cartridge filters be used for sterile gas applications?

Yes, cartridge filters have a highly effective microbial retention capacity to effectively remove microbial contaminants from the air, ensuring a sterile environment. In addition, Sanitek PTFE cartridge filters have good chemical and can be used under a variety of harsh process conditions. Therefore, for applications requiring sterile gases, Sanitek PTFE cartridge filters are a reliable choice.

Need Help?

You can find the right application or product using our Tool, or through our Chat Bot.

Let's help you find the right filter for
your critical filtration.

Talk to us

error: Content is protected !!
Open chat
Scan the code
Hello
Can we help you?